New spool of Commscope fiber optic cable 14,650'/4466M spec D-012-LA-8W-F12NS 12 fiber.
Commscope fiber optic cable, 12 strands/fibers, model D-012-LA-8W-F12NS. Label on reel states 15,594'. Cable on spool starts at footage marker 000950'.
Always kept covered.
The following engineering specs/data is from the Commscope website.
"Fiber OSP cable, LightScope ZWP® Single Jacket/Single Armor, GelFree, Stranded Loose Tube, 12 fibers, Singlemode G.652.D and G.657.A1, Feet jacket marking, Black jacket color.
Commscope fiber OSP cable, 12 fibers.
Product series: D-LA
General Specifications:
Armor Type- Corrugated steel
Cable Type- Stranded loose tube
Construction Type Armored
Fiber Type, quantity- 12
Fibers per Subunit, quantity -12
Filler, quantity- 4
Jacket Color- Black
Jacket Marking -Feet
Subunit Type Gel-free
Subunit, quantity- 1
Total Fiber Count- 12
Dimensions
Buffer Tube/Subunit Diameter 2.5 mm | 0.098 in
Diameter Over Jacket 11.5 mm | 0.453 in
Jacket material: PE
Mechanical Specifications:
Minimum Bend Radius, loaded 173 mm | 6.811 in
Minimum Bend Radius, unloaded 115 mm | 4.528 in
Tensile Load, long term, maximum 800 N | 179.847 lbf
Tensile Load, short term, maximum 2700 N | 606.984 lbf
Compression 44 N/mm | 251.246 lb/in
Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex 35 cycles Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact 4.41 N-m | 39.032 in lb
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles Twist Test Method FOTP-85 | IEC 60794-1 E7
Vertical Rise, maximum 740 m | 2,427.822 ft
Optical Specifications:
Fiber Type G.652.D and G.657.A1 | G.652.D and G.657.A1
Environmental Specifications
Installation temperature -30 °C to +70 °C (-22 °F to +158 °F)
Operating Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature -40 °C to +75 °C (-40 °F to +167 °F)
Cable Qualification Standards ANSI/ICEA S-87-640 | EN 187105 | Telcordia GR-20
Environmental Space Aerial, lashed | Buried Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penetration Test Method FOTP-82 | IEC 60794-1 F5
Environmental Test Specifications
Cable Freeze -2 °C | 28.4 °F
Cable Freeze Test Method FOTP-98 | IEC 60794-1 F15
Heat Age -40 °C to +85 °C (-40 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend -30 °C to +60 °C (-22 °F to +140 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle -40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1
Cable weight 110 kg/km | 73.917 lb/kft
Regulatory Compliance/Certifications:
CHINA-ROHS Below maximum concentration value
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
ROHS Compliant
8107297/DB | D-012-LA-8W-F12NS